But this time i would like to do a neater job.
Running conduit on a flat roof.
Seanb 1 don t forget the coil of cable and add a few ferrite toroids over the cable as well.
This is important when running the cable up the side of a house or across a roof.
At the moment the gutter drain pipe from the roof of the main property is running above the flat roof then is diverted along a drain pipe diagonally along the back external wall of the prerogative to a drain halfway along the property very ugly.
I m in florida and i have installed thousands of feet of pvc on roof tops.
In the past i ve put down 1 foot long pieces of treated 2x4 every 5 feet and ran pvc conduit.
Does the nec specify a clearance between the bottom of roof decking and electrical conduit.
The only reason we haven t install emt was because of the salt air.
If you aren t burying the cable choose a waterproof cat 6 cable that has a uv protective jacket to prevent damage from sunlight exposure.
Hi currently at the side of our house there is a large utility extension from the garage extending 2 3m into the garden.
I m a lv contractor and will be installing a cctv system on a building with a flat roof with a parapet.
So i m planning on running all camera wires in pvc schedule 40 either.
We are replacing part of the plant roof and some of the 277 lighting conduit runs along the bottom of the roof decking.
I can tell you real quick like it gets brittle after around 5 years.
Also cutting and roof system removal.
Mounting conduit on existing flat roof any time you see a thin black line to the left of a paragraph in the nec it means that it s new or the wording has changed.
Self cutting or self drilling roof fasten ers can readily penetrate metals of these thicknesses.
I cannot run it on the side of a parapet.
Exterior grade ethernet cables are waterproof and can be buried in the ground without a conduit.
By way of comparison the wall thick ness of 1 2 inch thick metallic conduit is comparable to the metal thickness of a 20 gauge steel roof deck.
The system will use cat 6 to each camera and running these wires indoors is impractical in most of the building.
Running conduit through roof reply 5 on.
I have to run a circuit to supply power to a sign across about 50 feet of flat roof.
August 02 2011 09 56 26 am author.
If your lucky you will get 10 years service out of roof mounted pvc conduit in florida.
Lic conduit embedded within or directly underneath roof assemblies.
I am worried about a roofer running a screw into the conduit as they secure the insulation.